I have a 750V, 4A high-voltage DC power supply. What topology is more appropriate?
Michelle 게시 날짜 August 3, 2020
If the output range is narrow, let's LLC.
Jenna 게시 날짜 August 3, 2020
It is recommended to use LLC with secondary rectification and then series connection. For example, there are two windings on the secondary side. One winding generates 350V and the other winding generates 350V. There is no center tap, and each uses bridge rectification. This will require 8 fast rectifier diodes. As shown:
Colin 게시 날짜 August 3, 2020
Yes, series connection after secondary rectification is a good choice. If the secondary does not have a center tap, the secondary transformer can be directly connected in series and then rectified, which can reduce rectifiers,