견적 요청 / BOM 0 로그인 / 등록하다

귀하의 위치를 선택하세요

사용자 이미지

How do you see the parameters of the mos tube?

Hardware design
7월 30, 2020 by Laurence 803

Why is Vds too low in the figure? It's not that the maximum current in the table above is exceeded by tens of A with a voltage tube.

IS9A8KKUK8O6]PXB$]SA{2L.png BA1PR$}GSRBH7LMCL{A9QJR.png

모든 댓글

user image

Rachelle 게시 날짜 July 30, 2020

This is the characteristic of the drain conduction region.

0
user image

Dianna 게시 날짜 July 30, 2020

This is the characteristic of the tube. Therefore, the appropriate Vds and Vgs should be selected during use in order to achieve the appropriate current.

0
user image

Clifford 게시 날짜 July 30, 2020

The table is the limit operating parameters of the device, it is not allowed to operate according to this parameter, the device will be damaged; the figure is the characteristics of drain-source voltage and drain current under different gate-source voltages.

0

답변 작성

답글을 달려면 로그인이 필요합니다. 로그인 | 등록하다