RFQ/BOM 0 로그인 / 등록하다

귀하의 위치를 선택하세요

사용자 이미지

Can the reverse power protection circuit in the picture work normally?

Hardware design
7월 13, 2020 by Birdie 416

During normal operation, Q5 is on, U1 is on, D12V0 is 12V,

When the input is reversed, the D35 conduction clamp is at a few V, Q5 is turned off, and U1 is not turned on to complete the protection.

Q5 Will it withstand reverse voltage when it is connected in reverse?

모든 댓글

user image

Delon 게시 날짜 July 13, 2020

Except for U1, all the devices on the left are removed, and it is sufficient to ground the U1 pin 4 with a resistor.

0
  • Misa

    Misa 게시 날짜 July 13, 2020

    Like, great

  • 답글을 달려면 로그인이 필요합니다. 로그인 | 등록하다

user image

Alphonse 게시 날짜 July 13, 2020

When Q5 is connected in reverse, U1 will burn down, and the internal freewheeling diode of u1 will be directly added by the voltage of Q5, which will burn down the freewheeling diode.

0
user image

Serra 게시 날짜 July 13, 2020

If conditions permit, add a diode to the power supply input to protect the point; the reverse cut-off, no loop.

0

답변 작성

답글을 달려면 로그인이 필요합니다. 로그인 | 등록하다