MOS tube switching circuit, the conduction of the tube will cause the MCU to trigger an interrupt?

MCU
9월 18, 2020 by Jaydon 1741

As shown in the figure below, is there any problem with the circuit principle? When the hand touches the lead of the G terminal, the conduction of the tube causes the MCU to trigger an interrupt.

모든 댓글

user image

Mekhi 게시 날짜 September 18, 2020

Encountered before, R17 was changed to a smaller one, such as 10k or smaller.

0
user image

Kaya 게시 날짜 September 18, 2020

R17 is connected to a capacitor, such as 1000p. The capacity should be as large as possible without affecting the switching speed of the tube. The smaller the R/the larger the capacitor, the better the anti-static interference, but the switching speed of Q1 will have an impact.

0
user image

Javon 게시 날짜 September 18, 2020

The MOS tube caused by this static electricity is turned on by mistake, generally it is fine to connect a pull-down resistor, and also a capacitor.