RFQ/BOM 0 로그인 / 등록하다

귀하의 위치를 선택하세요

사용자 이미지

For some power protection chips, is there a design difference between over-current protection and short-circuit protection?

Hardware design
11월 04, 2020 by Luther 1572

I tested an over-current and over-voltage protection chip, and connected a small resistor to the output terminal to make it over-current. After the chip is turned off, it starts to detect current every 2 seconds, but if I short-circuit the output terminal directly, the frequency of the chip's startup detection will be It is greatly shortened, and the detection time will be greatly extended, resulting in serious heating of the chip.

I think that short circuit is nothing more than an extreme case of overcurrent, and the chip processing mechanism should be the same. But the performance difference on this chip is very big.

Are there anyone who can share their insights~~~

모든 댓글

user image

Cate 게시 날짜 November 4, 2020

Some ICs will adjust the detection frequency according to the current value.

0
user image

Keri 게시 날짜 November 4, 2020

The overcurrent is generally the current of the mirror MOS, and the short circuit can also detect the voltage drop of the output voltage.

0
user image

Monet 게시 날짜 November 4, 2020

This should be determined according to the size of the current, over-current stop vibration, short-circuit burn insurance.

0
user image

Herman 게시 날짜 November 4, 2020

The two are not copper, the overcurrent usually continues to output at a constant current, and the short-circuit protection may be constant current or cut off the output.

0