Why the higher the load current consumption, the lower the voltage?

Hardware design
11월 19, 2020 by Ester 1025

A 5V/3A adjustable power supply, after connecting to the device, the measured current consumption is 700ma, and the terminal voltage drops to 4.85-4.89V. If the instantaneous current reaches about 1A, the terminal voltage will instantly drop to 3.65-4.5V, which will cause the system to restart. Why is the voltage pulled down and the output power is enough?

모든 댓글

user image

Shah 게시 날짜 November 19, 2020

Consider the contact resistance of the clip and the line loss?

0
user image

Rahim 게시 날짜 November 19, 2020

Is it because the resistance is relatively large and the partial voltage is too large, which leads to low voltage in the subsequent stage, and the wiring should meet the maximum current. Another reason is that the power chip limits the current. You can use the load to test the maximum output current independently.

0
user image

Caspar 게시 날짜 November 19, 2020

4,85V is measured in what state, is the board working normally, it should not be able to enter the system normally with the same power supply, because it restarts when it takes an instant 1A.